Continuous process manufacturers rely on I-GARD’s High Resistance Grounding Systems (HRG) to help ensure continuity of operation by protecting against over voltages and reducing the risk of arcing ground faults.  

I-GARD HGR's: PATENTED, UNIQUE, DIFFERENT, BETTER
High Resistance Grounding

Protect your plant. Maintain your power. I-GARD'S High Resistance Grounding Systems allow you to detect and locate a ground fault without power interruption.

From Basic to the Ultimate in Protection, I-GARD has an HRG system to meet your needs. With the cost of arcing faults estimated at between $1 billion and $3 billion annually for equipment loss, production downtime and personal liability, you can't afford to take the risk.

A System For Every Application
Which HRG Is Right For You?



stoplight-sm.jpg


STOPLIGHT

  • Current limiting resistor
  • Integral ground fault relay

Learn more >



sleuth-sm.jpg


SLEUTH

  • Current limiting resistor
  • Integral ground fault relay
  • Fault location through pulsing
  • Harmonic filter and time / current adjustments to reduce false trips

Learn more >



fusion-md.jpg


FUSION

  • Patented Hybrid grounding System in a single enclosure
  • Current limiting device can be coordintated with downstream devices to select load to trip
  • Converst to high resistance grounding to maintain service continuity at user selected fault levels
  • Available with integral pulsing capability for easier fault location

Learn more >



gemini-sm.jpg


GEMINI

  • Dual Path current limiting resistor
  • Redundant fail-safe resistor circuit
  • Integral ground fault relay
  • Fault location through pulsing
  • Harmonic filter and time / current adjustments to reduce false trips

Learn more >



sentinal-sm.jpg


SENTINEL

  • Current limiting resistor
  • Voltage and current sensing
  • Integral ground fault relay
  • integral ground monitorning relay
  • Fault location through pulsing
  • Harmonic filter and time / current adjustments to reduce false trips
  • Inrush detection restraint
  • Modular and scalable
  • Multi-feeder protection
  • Second fault protection
  • MODBUS for remote monitoring.

Learn more >



c-460eb1-sm.jpg


ARTIFICAL NEUTRALS

  • Available transformer designs include Zigzag and Wye - Broken delta.
  • I-Gard artificial neutral transformers are Dry type vacuum resin impregnated. Special designs are available in a resin cast coil format in voltages of up to 35 kV.
  • Ideal solution in cases where Neutral point is not available.

Learn more >


 
 
 